Abcs Of Fire Sprinkler Hydraulic Calculations

By Young Lindsay


Many types of sprinklers that can be classified according to its activation temperature, fast opening, orifice size of sprinkler discharge or flow rate, type of fuse element, jet application form, coverage area waterjet among many other factors involved in risk analysis and project design by the specialist (fire sprinkler hydraulic calculations).

A fire sprinkler is a device for extinguishing fires. Consists of an armature, with a pipe connected to a water pipe pressure. The pipe is closed with a cover subject by a glass capsule filled with a liquid whose boiling point is at a certain temperature (temperature trigger) which is subject against a disperser. When a fire occurs, the liquid boils and the steam breaks the capsule; the lid bounces, exits the water and crashes into the disperser sprinkling the burned area.

It consists of a thermo-sensitive element that is designed to destroy at predetermined temperatures, automatically causing the release of plug and the outlet of a water spray, which should extinguish the flame right in area where it has started. This device can be of two types: side of a disassembled sprayer without bulb or fuse Vista.

Hence the name sprayed, which varies depending on the application that you want to give the system sprinkler. The most common use of these sprinkler-systems is the cooling of walls of a storage tank of flammable liquids because they are easier and less costly to maintain than a system of sprinklers, which moreover do not correspond to a pattern of dispersal water required by such facilities.

Therefore, in case of fire, after the destruction of temperature sensor, the lid remains tightly spray glued to the hull and the water from the system is not received. Such cases were reported in the fire at many places in USA. After that, the producers was conducted large-scale action to recall and replace all sprinklers with rubber sealing rings. In some countries the use of sprinklers with a rubber seal is prohibited.

These processes may take more or less depending on rate of release of surrounding heat to spray, the distance between the sprinkler and ceiling, the distance between the spray and the floor, the roof slope and other factors that have been extensively studied by the NFPA (National Fire Protection Association), UL (Underwriters Laboratories), FM (Factory Mutual), among other research and development in flame protection systems.

In protected space stretching combustible cord, which when blown open locks that hold the valve, the valve is released and the water flowed to a sprinkler. The device consisted of a cylindrical sealed tanks of about 95 tys.litrov system and 10-inch (250 mm) of the distribution of the aqueduct, covering all parts of the theater. Series of pipes of smaller diameter departed from the distribution pipes and were imbued with a number of half an inch (13 mm) holes through which poured water in case of fire. But the system was not automatic.

First installation started in late XIX century, after the Englishman Stuart Harrison in 1864, has developed a sprinklers. Further development of sprinkler systems associated with the names of Americans Henry Parmelee and Frederick Grinnell. By 1882 in the United States for 200 enterprises was established about 200 thousand. Sprinkler-design Parmelee. During the same year in England the first such installation was witnessed.